Part numberTypeName of product
C9100-12
This product is discontinued
High SensitivityBack-Thinned Electron Multiplier CCD Camera


Click image to enlarge

The C9100 series gather all expected features: high gain, high signal to noise ratio, resolution and speed, thanks to a new generation back-thinned EM-CCD sensor in a proprietary permanently sealed vacuum chamber evacuated to 10 -8 Torr.

With on-chip multiplication technology of the EM-CCD sensor the signal is drastically boosted while readout noise value is kept less than 1 electron r.m.s. at high gain mode. The gain factor of the C9100-12 is up to 2000 and this camera is able to grab 35 frames per second keeping 14 bit dynamic range and full resolution. The C9100-12 also supports sub-array and binning modes, which enable high frame rate,100 frames per second or higher.

The C9100-12 is recommended for all applications requiring high gain, speed, good resolution, high dynamics and signal to noise ratio.

 
 Datasheet:  229 KB 
 
 
Key Specifications Drawing

Part number C9100-12
Name of product Back-Thinned Electron Multiplier CCD Camera
Spectral response min 400nm
Spectral response max 1080nm
Features
  • High quantum efficiency
  • High sensitivity with on-chip multiplication
  • Electron multiplier gain max. 2000 times
  • Easy handling and maintenance
  • High resolution 512 (H) x 512 (V) pixel
  • Lifetime warranty for the sensor assembly
Applications
  • Intracellular ion imaging
  • Intravital microscopy (Real time observation of circulating blood cells in living animals)
  • Fast tracking of small particles
  • Single molecule observation at the photon level
  • High speed fluorescence cell tomography
Imaging device Frame transfer CCD. back-thinned
Shutter No
Horizontal number of pixels 512
Vertical number of pixels 512
Cell size - horizontal 16µm
Cell size - vertical 16µm
Effective Horizontal Size 8.192mm
Effective Vertical Size 8.192mm
Scan Mode 1 min. gain
Scan Mode 2 max. gain = 2000MHz
Pixel clock rate Scan Mode 1 11Fr/sec
Frame Rate Scan Mode 1 272.48 with binningr.m.s.
Read noise Scan Mode 1 40electrons
Read noise Scan Mode 2 <1electrons
Full well capacity Scan Mode 1 370
Full well capacity Scan Mode 2 400
A/D converter Scan Mode 1 14
A/D converter Scan Mode 2 14
Cooling Method Peltier, forced air cooling plus hermetic sealing
Cooling Temperature -50
Output type Camera link
Exposure time min 27 (1ms with external trigger)ms
Exposure time max 10secs
External control Camera link
Sub-array yes
Binning yes
External trigger yes
Contrast Enhancement No"Vac ; Hz"
Lens mount C-mount
Line voltage +12V DC


Click image to enlarge

 

   


 
 